this post was submitted on 29 Sep 2024
709 points (98.9% liked)

Lemmy Shitpost

26821 readers
4706 users here now

Welcome to Lemmy Shitpost. Here you can shitpost to your hearts content.

Anything and everything goes. Memes, Jokes, Vents and Banter. Though we still have to comply with lemmy.world instance rules. So behave!


Rules:

1. Be Respectful


Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.

Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.

...


2. No Illegal Content


Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.

That means:

-No promoting violence/threats against any individuals

-No CSA content or Revenge Porn

-No sharing private/personal information (Doxxing)

...


3. No Spam


Posting the same post, no matter the intent is against the rules.

-If you have posted content, please refrain from re-posting said content within this community.

-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.

-No posting Scams/Advertisements/Phishing Links/IP Grabbers

-No Bots, Bots will be banned from the community.

...


4. No Porn/ExplicitContent


-Do not post explicit content. Lemmy.World is not the instance for NSFW content.

-Do not post Gore or Shock Content.

...


5. No Enciting Harassment,Brigading, Doxxing or Witch Hunts


-Do not Brigade other Communities

-No calls to action against other communities/users within Lemmy or outside of Lemmy.

-No Witch Hunts against users/communities.

-No content that harasses members within or outside of the community.

...


6. NSFW should be behind NSFW tags.


-Content that is NSFW should be behind NSFW tags.

-Content that might be distressing should be kept behind NSFW tags.

...

If you see content that is a breach of the rules, please flag and report the comment and a moderator will take action where they can.


Also check out:

Partnered Communities:

1.Memes

2.Lemmy Review

3.Mildly Infuriating

4.Lemmy Be Wholesome

5.No Stupid Questions

6.You Should Know

7.Comedy Heaven

8.Credible Defense

9.Ten Forward

10.LinuxMemes (Linux themed memes)


Reach out to

All communities included on the sidebar are to be made in compliance with the instance rules. Striker

founded 1 year ago
MODERATORS
 
you are viewing a single comment's thread
view the rest of the comments
[–] nick@midwest.social 125 points 1 month ago* (last edited 1 month ago) (5 children)

This happens when the neutral goes out in a house. Usually the waterlines will handle it, but if the house has pex the ground will go through the gas lines.

Especially if a high voltage line comes down on a gas meter for whatever reason.

Definitely run away and call professional… everyone i guess.

[–] AngryCommieKender@lemmy.world 18 points 1 month ago (3 children)

Would killing the main breaker at least prevent the heating of the pipes so that the expert isn't walking into a potentially dangerous situation?

[–] ghterve@lemmy.world 19 points 1 month ago

I think in this case the power heating the pipes is not coming from this house's electrical service, so killing the main breaker probably won't help.

I'm a little concerned killing the main breaker might result in a sudden temperature change that might fracture the gas line. Of course if you turn the gas off you might get fried.

[–] Rai@lemmy.dbzer0.com 8 points 1 month ago

I read that this happened due to a downed power line. Unfortunately, killing the main breaker would not do anything.

[–] bobs_monkey@lemm.ee 11 points 1 month ago

We found out a while ago that plumbing pipes aren't the best way to ground a house for a variety of reasons, and this is why ufers (grounding to foundation steel) and ground rods are now the NEC standard. Also, this is why bonding wires are important as well. If the plumbing were bonded to a proper dwelling ground system, the current would find a direct path to ground and trip the responsible breaker, instead of using the gas lines as a big ass resistor and creating the light show we see here.

[–] David_Eight@lemmy.world 6 points 1 month ago (1 children)

I've never seen pex running into a house from the street/ground. It's always been copper up to the water meter at the very least and it's code (in NJ at least) to put grounding wire there.

[–] linearchaos@lemmy.world 3 points 1 month ago

I'm in a new development. It's all plastic.

[–] Anivia@feddit.org 3 points 1 month ago (1 children)

This would have also been prevented if the electrical install included an RCD. It would have tripped instantly when the neutral gets disconnected

[–] bobs_monkey@lemm.ee 1 points 1 month ago

Better yet to just have a bond to the gas and water pipes. In this instance, any current introduced to the plumbing has a direct connection to ground, which will allow current to flow freely and trip the breaker.

[–] Asifall@lemmy.world 1 points 1 month ago

Shouldn’t everything be grounded through the panel as well? I know I have a ground wire running out to a copper plate in the ground next to my house and my understanding was that if the neutral goes that would serve as the path to ground. Is this house missing that feature or am I wrong?