Meanwhile landlords: "one 50 year old outlet should be enough for two bedrooms right?*
No Stupid Questions
No such thing. Ask away!
!nostupidquestions is a community dedicated to being helpful and answering each others' questions on various topics.
The rules for posting and commenting, besides the rules defined here for lemmy.world, are as follows:
Rules (interactive)
Rule 1- All posts must be legitimate questions. All post titles must include a question.
All posts must be legitimate questions, and all post titles must include a question. Questions that are joke or trolling questions, memes, song lyrics as title, etc. are not allowed here. See Rule 6 for all exceptions.
Rule 2- Your question subject cannot be illegal or NSFW material.
Your question subject cannot be illegal or NSFW material. You will be warned first, banned second.
Rule 3- Do not seek mental, medical and professional help here.
Do not seek mental, medical and professional help here. Breaking this rule will not get you or your post removed, but it will put you at risk, and possibly in danger.
Rule 4- No self promotion or upvote-farming of any kind.
That's it.
Rule 5- No baiting or sealioning or promoting an agenda.
Questions which, instead of being of an innocuous nature, are specifically intended (based on reports and in the opinion of our crack moderation team) to bait users into ideological wars on charged political topics will be removed and the authors warned - or banned - depending on severity.
Rule 6- Regarding META posts and joke questions.
Provided it is about the community itself, you may post non-question posts using the [META] tag on your post title.
On fridays, you are allowed to post meme and troll questions, on the condition that it's in text format only, and conforms with our other rules. These posts MUST include the [NSQ Friday] tag in their title.
If you post a serious question on friday and are looking only for legitimate answers, then please include the [Serious] tag on your post. Irrelevant replies will then be removed by moderators.
Rule 7- You can't intentionally annoy, mock, or harass other members.
If you intentionally annoy, mock, harass, or discriminate against any individual member, you will be removed.
Likewise, if you are a member, sympathiser or a resemblant of a movement that is known to largely hate, mock, discriminate against, and/or want to take lives of a group of people, and you were provably vocal about your hate, then you will be banned on sight.
Rule 8- All comments should try to stay relevant to their parent content.
Rule 9- Reposts from other platforms are not allowed.
Let everyone have their own content.
Rule 10- Majority of bots aren't allowed to participate here.
Credits
Our breathtaking icon was bestowed upon us by @Cevilia!
The greatest banner of all time: by @TheOneWithTheHair!
This, along with hotels that hide their only power point behind the bed but have 50 bloody phone jacks, are my pet peeves. But it kinda makes sense when you consider they were mostly built before the days of having a ton of devices in the bedroom. A lamp and alarm clock, maybe a TV if you're well off, would've been perfectly fine for a lot of people
The absolute worst is when the Word Documents are stashed away in some random drawer. Or when you find an Excel spreadsheet under the mattress!
Not so awful, but it's disappointing when you open the drawer expecting a Bible, but there's only OneNote there.
Years ago, I used to play live music. We played in a lot of shitty dive bars. Thinking back on all the ancient decrepit plugs we used to power our instruments, amplifiers, and stage lights with...it's a miracle we never started a fire. Nightmare fuel now that I'm older and a little bit wiser.
There are two things going on here.
The first is that yes, more connections causes more opportunities for the plugs to slip. So you can get short circuits or even arcing that can start a fire.
The second is that the wire in the cord has a certain rating on it. Many of those cords do not use 12 (20 amp) or 14 (15 amp) gauge wire; so, they're not rated for the full capacity of the wire in the wall. The breakers are sized to protect the wires in the wall, they don't know anything about the things plugged into them. So what can happen is you plug too much into the extension cord (particularly if it's a power strip) and the load on the extension cord is not enough to trip the breaker (because the walls are fine) but it's enough to overload the extension cord wire. In other words, the extension cord can start getting so hot it melts and possibly arcs up as the insulation fails.
You can have a fire from overloading a single power strip in just the same way. However, the more you chain together, the more likely you are to overload the power strip.
Ideally, you just think about what you're doing... But historically the easy answer is just to tell people not to chain things.
In short it's not about the distance, it's about the insulation and quality of the wire itself along with the number of connections.
First, I'm not an electrician, or anything even vaguely approaching one.
I've never heard that advice with extension cords, only power strips.
You could theoretically link enough extension cords together to cause problems, but it would need to be some extremely shit extension cords or a LOT of them. Resistance increases over distance, which in power cables manifests as them getting hotter. That isn't a problem until all the sudden it is a problem.
For power strips, the main danger is that you're potentially introducing more outlets than any of them are rated for. If you're just using 2 3ft power bars to functionally make a 6ft cable that you're only plugging a single thing into.. you're fine. Or at least I was, idk I did it for like a whole year. If you're plugging 16 things into a single wall outlet via power strips you can trip the circuit breaker, or potentially much worse stuff can happen like things getting melty and starting a fire.
If you know enough of what you're doing to math out the power draw+what your outlet/power strips are rated for you can pretty (afaik) safely daisy chain them if you wanna.
Yeah, there are two components here
- Adding extra length.
- Adding more outlets.
2 is the main problem, but you need a little of 1 to have it fail in an unsafe way (ie. not just tripping the circuit breaker).
If you just add a lot of extra outlets and plug lots of stuff in then you will simply trip the circuit breaker. (Assuming that everything is properly set up according to code.) In order to create a problem you need some extra wiring that is rated for less load than the wall wiring. (Now in practice every splitter has some amount of wiring, so these can be the same device, but most power bars are rated to be "fully used" or have a fuse internally). So the problem looks something like this:
- Have a 20A wall circuit.
- Plug a 10A extension cord into it.
- Plug a power bar or other splitter into the extension cord.
- Put enough devices into the splitter to generate 15A of current.
Now you are overloading the extension cord and risking fire.
The smart answer: it can start a fire, don't do it.
The honest answer: I've done it a zillion times and never started a fire. I buy heavy 12 and 10 gauge cords and only chain them to power things that don't require a lot of amps, like LED lights.
When in doubt, a plug-in power meter is an option you can use to help monitor the situation. Plugs that draw a lot of amps can get warm, even when not using an extension cord. Also, it's not uncommon for a device to pull a lot of amps on initial power-up, and then settle down to a lower draw.
I'm not trying to be ignorant, I'm just curious.
I think you're in the right community! Don't let anyone tell you to shy away from asking curious questions. (well, unless the question is also bigoted, illegal, baiting, sealioning, or otherwise disingenuous)
I'm not an electrician in any jurisdiction, but one answer for why two 2-meter (~6 ft) extension cords in series is inadvisable compared to a single 4 meter cord is that it's not an apples-to-apples comparison. Longer cords necessarily have to be built differently than shorter cords, not only because of electrical codes (eg the NEC in USA) or product safety specs (eg UL, CSA) but also being well-designed for their expected use. There's also the human aspect, which all good designs must account for as well.
Here in the USA, common extension cord lengths are ~2 m (6 ft), ~7.5 m (25 ft), ~15 m (50 ft), and ~30 m (100 ft). Of those cords, the common wire gauge used might be 18 AWG (~1 mm^2), 14 AWG (~2 mm^2), 16 AWG (~1.5 mm^2), and 12 AWG (~3.5 mm^2). I've intentionally rounded the metric units so they're more analogous to common wire gauges outside the USA. Finally, the insulation used can be anything from "thin, indoor only" to "heavy, abrasion and sunlight resistant". And while the USA technically has a boat-load of AC connectors, the grand majority will use the standard 2-pin or 3-pin 120v connector, formally known as NEMA 1-15 and NEMA 5-15 respectively. What this means is that chaining extension cords is both possible and somewhat common. The problem is one of mismatched designs.
From a cursory search on the website of a major USA home improvement store, the smallest wire gauge used for a 100 ft cable is 16 AWG. The largest is 10 AWG (nb: smaller numbers mean bigger wire). That thinner cable is marketed for outdoor use. The thicker cable indicates its use "indoor/outdoor" and for heavy-duty applications. It is also branded with a major power-tool company, which would be appropriate as power tools often draw high current.
Whereas looking at 6 ft extension cords, most are 16 AWG but a few were 18 AWG (thinner than 16) or 14 AWG (thicker). But I could not find any thicker cables than that, certainly nothing that uses 10 AWG (~6 mm^2). The "heavy duty" cables of this length also used only 16 AWG wire.
Because electrical resistance is additive in series, and because Ohm's Law governs the voltage lost at the end of a cord, the use of insufficiently large conductors can cause voltage issues for high-current appliances. Appliances for USA-spec generally require 120 Volts +/- 10%, with utilities aiming to provide 120 Volts +/- 5% from the outlets. This means a "sufficient" power cord should not have a voltage drop of more than 6 volts, give or take. Of course, a high-current appliance will also cause a larger voltage drop than a low-current device, so we only consider the former case.
For a machine that draws 12 Amps attached to a 100 ft extension cord made of 18 AWG wire, the voltage drop would be 15 volts. This is bad for the machine, which now sees a lower voltage than expected. Had the cord been made of 12 AWG wire, the drop is an acceptable 3 volts.
So if you're operating construction tools, it would be a terrible idea to use three random 6-ft cables, and you should instead use a single 25-ft cable. Even though it's longer than you need, the fact is that most 25 ft cables use thicker conductors, which reduces the voltage drop overall.
But there's also that peaky human factor. Sure, there would also be more connectors which could come loose, but the really pressing issue with daisy chained cords is when people do that indoors, because they only have light-duty 6 ft cables handy. And for that Christmas tree, they need to use attach three cables together to go beneath the hallway rug.
This is essentially the worst-case scenario: using thin conductor cords, with thin insulation, underneath very flammable household surfaces, which are also trodden upon by foot traffic. Every step on that cord weakens the insulation and fatigues the conductors. Over time, the conductor becomes thinner where it's being fatigued, and this increases the voltage drop. An unfortunate result of a voltage drop is that it generates heat. For a cable which is uniformly thin, this heat is spread over the whole length. But for localized conductor damage, the heat is pin-point... directly under a flammable rug.
In the USA, some 3300 house fires started from an extension cord. Because these cords are not within the walls, they are usually beyond the control of often-strict building/electrical codes, something that's been critiqued by a prominent YouTuber. The US CPSC even goes so far as to create memes to promote their messaging that space heaters -- a common, high-current appliance -- should not be used with extension cords or strips.
Of course, from an electrical perspective, even a ten-long chain of dinky extension cords would have no problem powering just a single LED night light. But it's reasonable to ask: 1) is this just asking to be struck down by fate, 2) are there better alternatives like thicker/longer cords, and 3) why isn't there an outlet where you need it?
(There's also a scenario where too long or thin of an extension cord can cause a circuit breaker to fail to trip during a short circuit, but it's fairly esoteric and this post is quite long now)
In short, the blanket recommendation to avoid daisy-chaining cords is to avoid the nasty and sometimes fatal results when that can go wrong, even with it might not always play out that way. There's almost always something safer than can be done than daisy chaining.
+1 for technology connections video. Was going to post the same link.
Resistance increases over longer distance cable, and increased load from appliances. (Especially don't with american electrics, they aren't fused so the wire can overheat and set fire to the surroundings.)
To clarify a bit, the benefit of the UK system isn't the end device having a fuse, but the cable itself having a fuse.
In the US the setup would be something like
- Wall has 20A wiring.
- Electrical panel has 20A fuse to avoid the wire in the wall from overheating.
- Extension cord is designed for 10A
- You plug in 2 10A devices to the extension cord.
- The wall wiring is fine, it can take 20A.
- The circuit breaker doesn't trip as it is also 20A.
- The extension cord overheats and starts a fire.
In the UK the 10A extension cord will have its own 10A fuse in the plug. So when you turn on the two 10A devices the fuse in the extension cord will blow and prevent the extension cord from overheating.
Bold of you to assume that the wall outlet would have a 20a breaker. Most don’t, unless they’re in a kitchen.
But you’re right about the resistance. Also, most extension cords are undersized for the loads they pull, they’re commonly made with 16 or even 18awg wire, further increasing resistance (which translates to heat).
Source: am electrician in US
The circuit power doesn't matter for the example. I was just picking easy numbers. You can have the same problem as long as the rating of the extension cord is less than the circuit breaker. (And as you pointed that out this is a very common case due to the frequently low rating of extension cords.)
I think it is partly a US specific problem as the quality of the extension cords really suck. Meanwhile in Eurpoe (or at least in Germany) the extension cords actually use the same wire grade as your in wall wires, so there is a basically no difference in using daisy chained extension cords versus different wall outlets (as long as the outlets are in the same curcuit)
Not necessarily exactly the same wires, but all rated for 16A, so the circuit beaker will trip long before any wire gets a chance to heat up
Yep, came here to write the same. We have 240V and not 120V like the US. To power the same appliance in the US you have double the Ampere and therefore higher risk of fire (correct me if I'm wrong)
I strongly disagree... We just have higher standards regarding power wires. Since we have more voltage running through the wires we need tougher ones, but that is what regulation is for
I always thought it was to stop people from plugging too many appliances into all the outlets.