Kinda looks like an impedance mismatch.
Thanks for taking a look! SG is set to 50Ohm output, cable is 50Ohm, terminated "through" 50Ohm at scope end. Also, SG output looks normal on a different scope (same cable/terminator arrangement). Not sure what else I could do to match the impedance here.
Does this scope do Fourier analysis? If so, can you see which frequencies are being suppressed? Does this suppression at this frequency also occur with generated white noise?
Thanks! I tried but I don't see the effect with noise gen, maybe my measurement is not quite right. Simply punching in a couple of frequencies (60Hz and 200Hz) that I've already seen differ in amplitude with the Measure function also has different peak amplitudes in FFT output. Since the frequencies are so low I've verified stability of siggen amplitude output with an AC voltmeter and it's stable within 50uV or so, nowhere near the diff in magnitude measured by the scope. Hmm...